When planning a modern building project, one of the most critical decisions involves selecting the appropriate elevator system. The choice between Machine Room-Less (MRL) and traditional Machine Room (MR) elevators significantly impacts construction costs, building layout efficiency, maintenance requirements, and long-term operational expenses. This comprehensive guide explores the fundamental differences, advantages, and disadvantages of both systems to help you make an informed decision tailored to your specific project needs.

Passenger elevators have evolved dramatically over the past two decades. The emergence of MRL technology represents a paradigm shift in elevator design philosophy, challenging the conventional approach that had dominated the industry for nearly a century. Understanding these distinctions is essential for architects, engineers, developers, and facility managers who seek to optimize their building investments.

Understanding Traditional Machine Room (MR) Elevators

The Conventional Elevator Architecture

Traditional Machine Room elevators represent the established standard in vertical transportation. In this configuration, the elevator's motor, controller, and mechanical components are housed in a dedicated machine room, typically located directly above the elevator shaft or in an adjacent space on the top floor of the building.

Key Components of MR Systems

The traditional MR elevator system comprises several essential elements:

  • Traction machine (motor and gearbox assembly)
  • Brake system for safety and holding power
  • Rope sheaves and guide rails
  • Control cabinet and electrical distribution system
  • Dedicated machine room space (typically 80-120 square meters)
  • Hydraulic or mechanical door operators
  • Safety switches and monitoring systems

Operational Principles

In an MR system, the traction machine uses steel ropes to lift and lower the car. The motor operates at a relatively low speed (typically 30-50 RPM), providing smooth and reliable operation. The gearbox multiplies the torque, allowing efficient lifting of heavy loads. The brake engages automatically when the car stops, providing safe holding capacity even during power failures. This time-tested design has earned widespread trust across residential and commercial applications worldwide.

Space and Location Considerations

A dedicated machine room requires substantial floor space—typically equivalent to the footprint of one complete apartment or office unit. This space must be maintained at specific environmental conditions, including proper ventilation, temperature control, and humidity management. The machine room must accommodate not only the elevator machinery but also service personnel who perform regular maintenance, inspections, and repairs.

The Innovation of Machine Room-Less (MRL) Elevators

Revolutionary Design Philosophy

MRL elevator technology fundamentally reimagines the relationship between machinery and building space. By integrating the motor and control systems directly into the elevator car or within the shaft structure, MRL systems eliminate the need for a separate machine room. This innovation, developed through advanced engineering and materials science, has transformed elevator design since its introduction in the 1980s.

How MRL Systems Function

Instead of traditional rope-and-pulley mechanisms operating from above, MRL systems employ one of two primary technologies:

  • Gearless Direct Drive: The motor connects directly to the sheave without an intermediate gearbox, reducing mechanical complexity and maintenance requirements. This design enables smooth acceleration and precise leveling.
  • Compact Geared Systems: Smaller, more efficient gearing arrangements fit within the shaft structure or car itself, maintaining torque multiplication while reducing overall size requirements.

Spatial Integration and Benefits

By relocating mechanical components to the top of the shaft structure or into the car frame itself, MRL systems recover valuable building space. A typical MRL installation recovers 80-120 square meters that would otherwise be reserved for the machine room. This recovered space can be converted to rentable floor area, increasing the building's revenue-generating potential or providing additional functionality without increasing the building's overall footprint.

Environmental Adaptability

MRL systems prove particularly advantageous in challenging environmental conditions. They require no dedicated climate control, operate reliably in extreme temperatures (both hot and cold climates), and function effectively at high altitudes where air density affects cooling efficiency. This adaptability makes MRL technology especially valuable for projects in geographically diverse locations.

Detailed Comparison: MRL vs. MR Elevators

The following table presents a comprehensive comparison of key characteristics across multiple dimensions:

Feature MRL Elevators MR Elevators
Machine Room Required No Yes (80-120 m2)
Installation Speed Faster (3-4 weeks) Standard (4-6 weeks)
Initial Capital Cost 15-20% higher Standard baseline
Space Recovery Value High (additional rentable area) None (space is mandatory)
Maintenance Complexity Lower (fewer components) Standard (established procedures)
Annual Maintenance Cost 5-10% lower Standard baseline
Environmental Control Needs None required Ventilation and cooling needed
Typical Speed Range 1.0-4.0 m/s 1.0-4.0 m/s
Load Capacity 1,000-2,500 kg 1,000-3,500 kg
Service Access Pit and top of car access Machine room access

Financial Analysis: Total Cost of Ownership

Initial Capital Investment

MRL elevators typically command a premium of 15-20% over traditional MR systems during initial purchase and installation. This higher upfront cost reflects the advanced engineering, specialized components, and sophisticated control systems required. For a typical commercial building project, this premium ranges from $15,000 to $35,000 per unit, depending on specifications and installation complexity.

Space-Related Economic Value

The most significant economic advantage of MRL systems emerges from recovered building space. In commercial real estate markets with values ranging from $300 to $1,000 per square meter annually, the elimination of an 80-120 square meter machine room generates substantial financial benefits:

  • Additional annual rental revenue: $24,000 to $120,000 per elevator unit
  • Capital value increase: $300,000 to $1.2 million per elevator (depending on market conditions)
  • Payback period for premium cost: typically 1-3 years in commercial markets
  • Long-term asset appreciation: recovered space appreciates with building value

Maintenance and Operational Expenses

MRL systems demonstrate superior long-term operational economics through reduced maintenance requirements. The absence of a gearbox, reduced mechanical complexity, and fewer lubrication points contribute to:

  • Annual maintenance savings: 5-10% compared to MR systems
  • Reduced downtime frequency due to simplified mechanics
  • Lower replacement parts costs over the equipment lifecycle
  • Decreased emergency repair incidents
  • Environmental control cost elimination

Lifecycle Cost Analysis

Over a 20-year elevator lifecycle, the total cost analysis typically favors MRL systems in urban commercial environments:

  • Year 1-3: MR systems appear more economical due to lower initial costs
  • Year 4-10: MRL systems recover the initial premium through space rental value
  • Year 11-20: MRL systems demonstrate superior cumulative financial performance through maintenance savings and property appreciation
  • Overall 20-year benefit: $100,000 to $500,000 per unit in typical commercial markets

Optimal Applications: MRL vs. MR in Different Building Types

Commercial Passenger Elevator Requirements

Commercial buildings—including office towers, shopping centers, and hospitality facilities—present compelling cases for MRL technology evaluation. In these environments, every square meter of space translates directly to revenue generation. The space recovery advantage of MRL systems becomes decisive, especially in metropolitan areas where real estate values are highest.

Commercial MRL Advantages:

  • Maximizes rentable floor area and building value
  • Reduces architectural constraints and design limitations
  • Enables flexible floor layouts without machine room accommodation
  • Supports modern, open-plan office configurations
  • Enhances building sustainability credentials

Commercial MR Advantages:

  • Established maintenance networks and technician familiarity
  • Lower initial capital investment
  • Available high-capacity options (up to 3,500 kg)
  • Proven performance in extreme-use environments

Residential Passenger Elevator Applications

In residential passenger elevator projects, the decision between MRL and MR systems depends on building height, density, and market positioning.

MRL Suitability in Residential Projects:

  • Mid-rise residential buildings (8-25 stories)
  • Urban luxury apartment developments
  • Mixed-use residential-commercial projects
  • Space-constrained urban infill projects
  • Sustainable and green-certified residential buildings

MR Suitability in Residential Projects:

  • High-rise residential towers (25+ stories)
  • Buildings with existing machine room infrastructure
  • Projects with lower cost sensitivity
  • Developments requiring ultra-high-capacity elevators
  • Buildings in regions with established MR maintenance traditions

High-Speed Passenger Elevator Considerations

High-speed passenger elevators operating at 3.5-4.0 m/s or higher present unique considerations. While both MRL and MR systems can accommodate these speeds, traditional MR configurations dominate in ultra-high-speed applications due to established engineering practices and proven performance at extreme speeds. However, advanced MRL technology continues expanding into higher-speed markets.

Small Machine Room Solutions

An intermediate category exists between traditional MR and full MRL systems: small machine room passenger elevators. These systems compress machine components into a smaller footprint (20-40 square meters) located within or adjacent to the shaft structure. This approach offers:

  • Moderate space recovery compared to full MRL systems
  • Lower initial cost than full MRL systems
  • Established maintenance protocols and wider technician availability
  • Flexibility for retrofit applications
  • Effective compromise for transitional projects

Technical Advantages and Performance Characteristics

Speed and Acceleration Profiles

Both MRL and MR systems achieve comparable speed ranges (1.0-4.0 m/s for standard passenger elevators), with acceleration characteristics determined by passenger comfort considerations rather than mechanical constraints. Modern MRL systems employ sophisticated variable frequency drives (VFDs) that provide smoother acceleration curves and reduced mechanical stress compared to traditional systems.

Energy Efficiency Performance

MRL systems demonstrate superior energy efficiency through multiple mechanisms:

  • Direct Drive Advantage: Gearless systems eliminate gearbox friction losses, improving overall efficiency by 10-15%
  • Regenerative Braking: Modern MRL units capture kinetic energy during descent, returning power to building systems
  • Reduced Standby Consumption: Simplified control systems consume less power during idle periods
  • Thermal Management: More efficient cooling requirements reduce auxiliary energy demands

Safety and Redundancy Systems

Both systems incorporate comprehensive safety features, though implementation approaches differ:

MRL Safety Features:

  • Multiple mechanical lock systems along the shaft
  • Integrated emergency descent capability (backup power systems)
  • Sophisticated load-weighing and imbalance detection
  • Advanced door safety sensors and interlock mechanisms

MR Safety Features:

  • Proven, well-established safety protocols (century-old technology)
  • Redundant brake systems and mechanical stops
  • Accessible emergency manual operation from machine room
  • Wide familiarity among service technicians with safety procedures

Noise and Vibration Characteristics

MRL systems generally produce lower operational noise levels due to:

  • Absence of gearbox mechanical noise
  • Direct motor-to-sheave coupling reducing vibration transmission
  • Advanced damping systems integrated into car suspension
  • No machine room ventilation fans generating ambient noise

MR systems may generate higher noise levels, particularly with geared machines, though modern designs continue improving acoustic performance through isolation mounts and improved bearing designs.

Installation Timeline, Logistics, and Implementation Considerations

Installation Duration Comparison

MRL systems typically accelerate project timelines through simplified installation procedures:

  • MRL Installation: 3-4 weeks from delivery to operational testing
  • MR Installation: 4-6 weeks including machine room preparation
  • Time Savings: 15-25% faster deployment with MRL systems
  • Impact: Reduced construction financing costs and faster revenue generation

Logistical Advantages of MRL Systems

The elimination of machine room requirements simplifies site logistics significantly:

  • Reduced equipment delivery requirements
  • Simplified shaft preparation procedures
  • Minimal structural reinforcement modifications
  • Reduced site space requirements for installation equipment and staging
  • Faster coordination between elevator installation and other trades

Retrofit and Modernization Scenarios

When upgrading existing buildings, MRL technology offers distinct advantages for constrained environments. Building renovations and modernization projects often encounter space limitations that MRL systems accommodate naturally. Small machine room elevators provide an intermediate solution for retrofits where full MRL integration proves impractical.

Maintenance, Service, and Long-Term Operations

Preventive Maintenance Protocols

MRL and MR systems both benefit from regular preventive maintenance, though implementation approaches differ substantially:

MRL Maintenance Requirements:

  • Semi-annual inspections (vs. quarterly for MR systems)
  • Simplified component checks due to fewer mechanical parts
  • No gearbox oil analysis or replacement cycles
  • Direct access to most components without machine room entry
  • Approximately 20-30% fewer maintenance hours annually

MR Maintenance Requirements:

  • Quarterly inspections and routine maintenance cycles
  • Gearbox oil sampling, analysis, and periodic replacement
  • Regular machine room climate system checks
  • Extensive mechanical component lubrication and adjustment
  • Established procedures familiar to most maintenance teams

Component Wear and Replacement Cycles

MRL systems demonstrate extended component lifecycles through reduced mechanical complexity:

  • Guide Rails: 20+ years (both systems)
  • Traction Sheaves: 15-20 years (MRL), 10-15 years (MR geared systems)
  • Brake Components: 8-12 years (both systems)
  • Control Electronics: 12-18 years (both systems)
  • Door Mechanisms: 10-15 years (both systems)
  • Gearbox (MR only): Typically 15-20 years

Emergency Service and Response

Service response and emergency handling capabilities differ between system types:

MRL Emergency Response:

  • Onboard emergency power enables passenger egress without machine room access
  • Simplified troubleshooting through integrated monitoring systems
  • Reduced on-site diagnostic requirements

MR Emergency Response:

  • Established emergency protocols and procedures widely understood
  • Direct manual access to mechanical systems for emergency intervention
  • Extensive technician training and experience base available

Technician Training and Certification

While MR systems benefit from broader technician familiarity due to longer market presence, MRL technician training has matured significantly. Modern service networks now provide comprehensive MRL certification programs. When evaluating system selection, verify local technician availability and training accessibility for your specific geographic location.

Regulatory Compliance, Safety Standards, and Code Requirements

International Safety Standards

Both MRL and MR elevators must comply with stringent international safety standards, including ISO 4190 series (Safety of lifts and escalators), EN 81 series (European standards), and national variations in major markets. These standards establish comprehensive requirements for:

  • Load capacity limits and testing procedures
  • Emergency descent and rescue systems
  • Pit safety and emergency egress provisions
  • Electrical safety and backup power requirements
  • Regular inspection and testing protocols

Regional Regulatory Variations

Regulations governing MRL systems vary significantly by jurisdiction:

Europe: Extensive MRL adoption with comprehensive regulatory framework supporting machine room-less installations in buildings up to 25+ stories

North America: MRL adoption growing but with varying provincial and state-level regulations; some jurisdictions impose height restrictions on MRL systems

Asia-Pacific: Rapidly expanding MRL market with developing regulatory frameworks accommodating emerging technologies

Compliance Due Diligence

Before finalizing system selection, conduct thorough regulatory verification:

  • Consult local building codes and elevator regulations
  • Engage with relevant building authorities during design phase
  • Verify MRL system certification in your specific jurisdiction
  • Confirm technician licensing and certification requirements
  • Understand periodic inspection and testing mandates

Environmental Impact and Sustainability Considerations

Energy Consumption Analysis

MRL systems demonstrate measurable environmental advantages through reduced energy consumption:

  • Operational Energy: 10-15% reduction through improved mechanical efficiency
  • Auxiliary Energy: Elimination of machine room climate control systems
  • Regenerative Systems: Capture and reuse of kinetic energy during descent (advanced MRL units)
  • Annual CO2 Reduction: Approximately 5-10 metric tons per elevator annually (depending on usage patterns)

Material Efficiency and Waste Reduction

The streamlined design of MRL systems reduces material consumption:

  • Fewer mechanical components reduce manufacturing waste
  • Eliminated machine room reduces structural steel requirements
  • Simplified design facilitates end-of-life component recycling
  • Direct-drive technology eliminates gearbox oil, reducing hazardous waste

Building-Level Environmental Benefits

Selection of MRL systems contributes to broader building sustainability achievements:

  • Improved LEED and other green building certification scores
  • Reduced HVAC system sizing requirements (no machine room cooling)
  • Enhanced building energy efficiency ratings
  • Demonstration of commitment to environmental responsibility
  • Potential qualification for green building incentives and tax benefits

Decision Framework: Selecting the Optimal System for Your Project

Key Decision Criteria

Evaluate your project against the following primary criteria:

Decision Factor Favors MRL Favors MR Neutral/Context-Dependent
Space Cost Premium High commercial value Low-value space or unlimited area Moderate space value
Building Height 8-25 stories 25+ stories Low-rise (under 8 stories)
Capital Budget Priority Long-term value emphasis Immediate cost minimization Balanced approach
Project Timeline Accelerated schedules Standard timelines Flexible schedules
Regulatory Environment MRL-friendly jurisdictions MR-centric regions Flexible regulations
Local Service Infrastructure Established MRL technician networks Traditional MR service base Developing service options
Operational Philosophy Modern, efficiency-focused Proven, conservative approach Mixed priorities

Project-Specific Evaluation Process

Follow this structured approach to evaluate system suitability for your specific project:

Step 1: Quantify Space Economics

Calculate the financial value of recovered machine room space in your specific market and building type. Multiply 100 square meters by local annual rental rates or property values. If this value exceeds $25,000 annually or $250,000 in capital value, MRL economics likely favor your project.

Step 2: Assess Regulatory Feasibility

Contact your local building authority and confirm MRL compliance for your proposed building height and jurisdiction. Regulatory restrictions may eliminate MRL as an option regardless of economic benefits.

Step 3: Evaluate Technician Availability

Research local elevator service companies and verify MRL certification and experience in your region. Inadequate service infrastructure may create operational risks despite other system advantages.

Step 4: Calculate Total Cost of Ownership

Project costs over the elevator's 20-year lifecycle including initial purchase, installation, maintenance, energy, and space recovery value. Extend analysis to account for property appreciation and rental revenue changes over time.

Step 5: Consider Flexibility and Adaptability

Evaluate potential future building modifications, changes in use, and technology evolution. MRL systems may offer better adaptability to changing requirements due to compact design.

Practical Implementation Scenarios

Scenario 1: Urban Commercial Office Tower

A 20-story office tower in a metropolitan business district with premium space values ($500+ per square meter annually) planned four elevator units. Each machine room elimination recovers approximately 100 square meters, generating $200,000+ in annual rental value. The MRL premium cost of $60,000 per unit ($240,000 total) pays back within 12-14 months through recovered space alone. Additionally, faster installation accelerates lease commencement and rental revenue generation.

Recommendation: MRL systems provide compelling economic advantage

Scenario 2: Suburban Residential Complex

A 12-story mid-rise residential development in a suburban location with moderate property values ($150-250 per square meter annually). Two elevator units with machine room elimination recovering 90 square meters each provide moderate economic value ($27,000-45,000 annually). MRL premium cost of $30,000 per unit requires 8-16 months for space value recovery. Residential buyers typically prioritize additional unit space over operational efficiency.

Recommendation: MRL offers moderate advantage; MR remains competitive option

Scenario 3: Heritage Building Retrofit

A historic structure with strict height and facade constraints requires modern elevators within tight spatial limitations. Traditional machine room installation proves impossible due to heritage restrictions. Small machine room or full MRL systems become mandatory rather than optional, eliminating traditional MR as viable alternative.

Recommendation: MRL or small machine room systems required by project constraints

Scenario 4: High-Rise Luxury Residential Tower

A 35-story luxury residential tower requiring ultra-high-performance elevators with capacity of 2,500+ kg. MRL technology limitations at extreme heights and specific capacity requirements favor traditional MR systems. Space recovery benefits diminish when premium residential units command higher per-square-meter values than available alternative uses for elevator space.

Recommendation: Traditional MR systems better suited to project requirements

Implementation Checklist and Next Steps

Pre-Decision Planning Activities

  • Engage elevator consultants early in architectural design phase
  • Analyze local real estate market and space valuation
  • Contact building authorities for preliminary code guidance
  • Research local elevator service provider capabilities and availability
  • Conduct preliminary structural engineering assessment for system compatibility
  • Develop preliminary cost estimates and financial models for both systems
  • Identify future building modification or adaptive use scenarios
  • Establish decision timeline aligned with design phase milestones

Design Phase Verification

  • Prepare detailed elevator system specifications based on selected technology
  • Obtain formal building authority approval for selected system
  • Develop machine room design (if MR selected) or shaft verification (if MRL selected)
  • Integrate elevator requirements with architectural and structural design
  • Confirm utility connections and electrical requirements
  • Establish maintenance access requirements and procedures
  • Create operational and maintenance manuals for selected system
  • Finalize elevator equipment procurement and scheduling

Post-Selection Activities

  • Establish maintenance service contracts with qualified providers
  • Arrange technician training on selected system specifications
  • Develop preventive maintenance schedules and procedures
  • Plan emergency response protocols and procedures
  • Establish resident or occupant communication regarding elevator systems
  • Create documentation for facility management and future operations

Frequently Asked Questions

Q1: What does MRL stand for and how is it different from traditional elevators?

MRL stands for Machine Room-Less. Traditional elevators require a dedicated machine room (typically 80-120 square meters) to house the motor, gearbox, brake, and control systems. MRL elevators integrate these components directly into the elevator car or within the shaft structure, eliminating the need for separate machine room space. This fundamental design difference creates significant implications for building layout, construction costs, space utilization, and operational efficiency.

Q2: Are MRL elevators safe compared to traditional machines room elevators?

Yes, MRL elevators meet identical safety standards as traditional MR elevators. Both systems comply with international safety regulations (ISO 4190 series, EN 81 series, and national variations). MRL systems incorporate sophisticated mechanical lock systems, emergency descent capabilities, advanced monitoring systems, and multiple redundancies. The safety profile of modern MRL systems has been extensively validated through decades of global deployment and continuous improvement.

Q3: What is the cost difference between MRL and MR elevators?

MRL elevators typically cost 15-20% more than traditional MR elevators during initial purchase and installation ($15,000-35,000 premium per unit depending on specifications). However, this upfront cost difference is often recovered through the value of recovered building space within 1-3 years in commercial environments. Over a 20-year lifecycle, MRL systems typically provide superior total cost of ownership through space recovery, reduced maintenance costs, and improved energy efficiency.

Q4: Which system is better for high-rise buildings?

For buildings exceeding 25-30 stories, traditional MR systems remain the established standard. MRL technology is continuously expanding to higher heights, with modern systems now operating effectively up to 25+ stories, but ultra-high-rise applications (35+ stories) still typically favor MR systems. However, evaluate specific project requirements—some mid-rise applications benefit more from MRL despite traditional MR use at comparable heights elsewhere.

Q5: How much maintenance do MRL systems require?

MRL systems require less frequent maintenance than traditional MR systems. MRL systems typically require semi-annual inspections (compared to quarterly for MR systems) and eliminate many maintenance tasks such as gearbox oil changes and machine room climate system checks. Annual maintenance hours are typically 20-30% lower for MRL systems, translating to annual savings of 5-10% in maintenance costs.

Q6: Can MRL systems be installed in existing buildings during renovation?

MRL systems work well for some retrofit applications, particularly when space constraints limit traditional machine room installation. However, existing structural elements may complicate installation. Small machine room elevators (20-40 square meters) often provide better retrofit solutions by balancing space recovery with installation feasibility. Each retrofit project requires individual assessment of structural compatibility and spatial constraints.

Q7: What is the payback period for the higher MRL installation cost?

In commercial environments with high real estate values ($300+ per square meter annually), the space recovery value typically covers the MRL premium cost within 12-24 months. In residential or lower-value markets, payback extends to 3-5 years. Over the full 20-year elevator lifecycle, MRL systems generally demonstrate superior financial performance in most urban and metropolitan markets.

Q8: Are there geographic areas where MRL systems are not recommended?

Some regions maintain regulatory restrictions on MRL systems, particularly regarding building height limitations. Additionally, areas with limited MRL technician training and certification may present service challenges. Always verify local building codes and service infrastructure before finalizing system selection. Remote locations with sparse elevator service networks may favor traditional MR systems for which more technician familiarity exists.

Q9: How do MRL systems perform in extreme climates?

MRL systems demonstrate superior performance in extreme temperature environments (both hot and cold climates) because they require no dedicated climate control. Traditional MR systems require heated and cooled machine rooms to maintain component performance. High-altitude installations also favor MRL systems where air density impacts cooling efficiency of traditional systems. This adaptability makes MRL technology particularly valuable for geographically challenging locations.

Q10: What happens if power fails in an MRL elevator?

Modern MRL systems include onboard emergency descent capabilities, allowing passengers to safely exit to the nearest floor using backup power systems. This eliminates the need for external intervention to reach passengers during power failures. Traditional MR systems provide backup power options as well, but MRL systems' integrated approach often proves more efficient. Verify emergency power specifications with manufacturers for your specific application requirements.

Q11: Can I convert a building from MRL to MR or vice versa?

Converting existing systems proves expensive and impractical. MRL-to-MR conversion would require massive structural modifications to accommodate machine room construction and mechanical systems. MR-to-MRL conversion faces similar challenges requiring extensive component replacement. System selection should account for long-term stability, and conversion scenarios should not factor into primary decision criteria.

Q12: How do I know if my building is suitable for MRL installation?

Suitable MRL candidates include: 8-25 story buildings, space-constrained urban locations, projects where real estate value justifies premium installation cost, jurisdictions with MRL regulatory approval, and areas with available MRL service technicians. Unsuitable candidates include: very low-rise structures (where space savings don't justify cost), ultra-high-rise buildings (25+ stories), regions with MRL regulatory restrictions, and areas without MRL service infrastructure. Engage elevator consultants for formal suitability assessment.

Related Products

Passenger Elevator

Passenger Elevator

Tenau passenger elevators with small machine room have improved their performance by reducing area o...

Panoramic elevator

Panoramic elevator

Elegant structure with limitless scenic views Tenau sightseeing elevator adheres to the design prin...

Freight Elevator

Freight Elevator

Considerate designing This elevator is specifically designed for the transportation of cargoes, wit...

Car Elevator

Car Elevator

In the modern city, there are more and more cars. To solve the difficulty of parking, TENAU uses its...

Hospital Elevator

Hospital Elevator

High safety standard with sincere care Tenau high-quality medical elevator is developed on basis of...

Home Elevator

Home Elevator

Let’s construct a happy and harmonious life!Machine roomless intensive design, "electric home applia...

Escalator Summary

Escalator Summary

Urban flavor, charm scene TENAU serial escalators fully apply novel materials and advanced domestic...

Moving Walk Summary

Moving Walk Summary

As easy as in smooth ground, the everlasting popular design & qualityTENAU moving walk elevates ...

Passenger Elevator

Passenger Elevator

Professional Machine roomless passenger elevators companyTenau machine roomless passenger elevators ...

Panoramic Elevator

Panoramic Elevator

ATTRACTIVE & POPULAR TENAU Elevator sends out leaders' demeanor.It comes from innovative streng...

Freight Elevator

Freight Elevator

Vertical cargo transportation TENAU machine roomless freight elevators are in compact structure, ad...

Car Elevator

Car Elevator

In the modern city, there are more and more cars. To solve the difficulty of parking, TENAU uses its...

3D PANORAMA

Contact Us

*We respect your confidentiality and all information are protected.